3 days ago

  • ALTERATION PERMIT

    SIDEWALK BRIDGE 300LBS PER=PSF 250' ALONG N 15TH ST.- SHELTER PLATFORM PERMIT- ERECTION OF A SIDEWALK SHELTER PLATFORM AS PER ENGINEERED PLANS. STREETS DEPARTMENT PERMIT REQUIRED FOR SIDEWALK CLOSURE PRIOR TO THE START OF WORK.

    225-51 N 15TH ST Issued July 12, 2018 Comment

4 days ago

6 days ago

Jul 08

  • ZONING ADMIN REVIEW

    ADMINISTRATIVE REVIEW OF PREVIOUS ZONING PERMIT #555318 TO REMOVE THE PREVIOUSLY APPROVED UNDERGROUND PARKING GARAGE (14 PARKING SPACES) AND REMOVE THE LEED GOLD DESIGNATION. NO CHANGES TO PREVIOUSLY APPROVED BUILDING HEIGHT OR GROSS FLOOR AREA. NO CHANGE TO 12-STORY ADDITION TO EXISTING STRUCTURE FOR USE AS VISITOR ACCOMMODATION (HOTEL WITH 150 ROOMS) AND ACCESSORY FOOD AND BEVERAGE SERVICE FOR HOTEL PATRONS AND ALL USES AS PREVIOUSLY APPROVED.

    228-38 N 13TH ST Issued July 6, 2018 Comment

Jul 07

  • ALTERATION PERMIT

    FOR LEVEL II ALTERATIONS ON THE THIRD FLOOR LEVEL OF AN EXISTING HEALTH FACILITY. ALTERATIONS TO INCLUDE THE ERECTION OF PARTITION WALLS, PROVIDE FINISHES/FURNISHINGS AND ACCESSIBLITY IMPROVEMENTS THROUGHOUT. BUILDING IS FULLY SPRINKLERED. ALL WORK TO BE DONE PER APPROVED PLANS. IF FIELD CONDITIONS VARY CONTACT DESIGN ENGINEER PRIOR TO THE START OF ANY WORK. SEPARATE PERMITS REQUIRED FOR MECHANICAL, ELECTRICAL, PLUMBING AND FIRE SUPPRESSION WORK.

    1513-41 RACE ST Issued July 3, 2018 Comment
  • ALTERATION PERMIT

    FOR INTERIOR LEVEL 2 ALTERATIONS INCLUDING DEMOLITION OF EXISTING INTERIOR, NON-LOAD BEARING PARTITIONS AND FINISHES, NEW PARTITIONS, FLOOR./WALL FINISHES AND DOORS AS PER PLANS. SEPARATE PERMITS REQUIRED FOR ALL MECHANICAL, ELECTRICAL, PLUMBING AND FIRE SUPPRESSION WORK.

    1515 ARCH ST Issued July 5, 2018 Comment
  • SUPPRESSION PERMIT

    FOR INSTALLATION OF AUTOMATIC SPRINKLER & CLASS I MANUAL WET STANDPIPE SYSTEMS WITH TWO (2) INCH FIRE SERVICE LINE & BACKFLOW PREVENTION (BFP) ASSEMBLY TO SERVE APPROVED MULTI-FAMILY DWELLING WITH PARKING GARAGE. AUTOMATIC SPRINKLER SYSTEM & STANDPIPE SYSTME INSTALLATION PER NFPA 13/14.

    439-47 N 13TH ST Issued June 29, 2018 Comment
  • ELECTRICAL PERMIT

    FURNISH & INSTALL 88 CAT6 PLENUM CABLES FOR VOICE & DATA AS PER NEC 2008 CC DISTRICT

    1216-32 WOOD ST Issued June 28, 2018 Comment

Jun 24

  • ELECTRICAL PERMIT

    UPGRADE EXISTING 600AMP SERVICE TO 800AMP SERVICE AND ADD 6 MORE METER SOCKETS,WIRE AN OUTLETS,SWITCHES,LIGHTS FOR 6 ADDITIONAL AS PER 2008 NEC (CC DISTRICT) ADD ADDITIONAL SMOKES,PULLS,HORNS AND HORNS STROBES TO EXISTING FIRE ALARM SYSTEM AS PER NFPA72

    439-47 N 13TH ST Issued June 22, 2018 Comment

Jun 23

  • MECHANICAL PERMIT

    MECHANICAL HVAC AND RELATED DUCTWORK THROUGHOUT TENANT SPACE 'B' AS PER PLAN. SEE ALTERATION PERMIT AP#881318 FOR APPROVED PLANS.

    322-44 N BROAD ST Issued June 21, 2018 Comment
  • ALTERATION PERMIT

    TENANT FITOUT OF GROUND FLOOR SUITE B AS PER PLANS. SEPARATE PERMITS REQUIRED FOR ELECTRICAL, PLUMBING AND FIRE SUPPRESSION. PLANS FOR THE MECHANICAL PERMIT ISSUED UNDER AP#883517 ARE PART OF THIS ALTERATION PERMIT.

    322-44 N BROAD ST Issued June 21, 2018 Comment

Jun 22

  • ALTERATION PERMIT

    RENOVATION TO EXISTING UNDERGROUND TUNNEL THAT CONNECTS CHERRY ST BUILDING TO RACE ST BUILDING. ABOVE GRADE WORK LIMITED TO MINOR REPAIRS. ALL WORK TO BE DONE PER APPROVED PLANS. IF FIELD CONDITIONS VARY CONTACT DESIGN ENGINEER PRIOR TO THE START OF ANY WORK. SEPARATE PERMITS REQUIRED FOR ALL OTHER WORK.

    1508-20 RACE ST Issued June 19, 2018 Comment

Jun 17

  • SUPPRESSION PERMIT

    FOR INSTALLING BRANCH LINES AND SPRINKLERS TIED INTO THE EXISTING MAIN AND RISER WITH EXISTING FIRE PUMP, FDC AND BACK FLOOW PREVENTER WITHIN PAFA HAMILTON BUILDING LOWER LEVEL.ALL WORK SHALL BE ACCORDANCE WITH APPROVED PLANS, HYDRAULIC AND CALCULATIONS

    130-40 N BROAD ST Issued June 14, 2018 Comment

Jun 14

  • ALTERATION PERMIT

    FOR THE INFILL OF OPENNINGS OF EXISTING ELEVATOR SHAFTWAY WITH CMU AS PER APPROVED PLAN FOR MODERNIZATION OF EXISTING MANUAL FREIGHT ELEVATOR TO CREATE AUTOMATIC, HIGH SPEED PASSENGER ELEVATOR. APPROVAL FROM THE DEPARTMENT OF LABOR AND INDUSTRY IS REQUIRED FOR THE CONSTRUCTION AND USE OF THE ELEVATOR.

    330-48 N 12TH ST Issued June 11, 2018 Comment
  • ZONING/USE PERMIT

    1 ERECTION OF 1 ACCESSORY FLAT WALL INTERNALLY ILLUMENTED SIGN AS PER PLANS

    127 N 15TH ST Issued June 11, 2018 Comment

Jun 13

  • ELECTRICAL PERMIT

    70 SPEAKERS,3 TOUCH PADS,3 AMPS ,1 MUSIC RACK,1 MICROPHONE AND 7 TV'S PER 2008 NEC (RESTAURANT)

    219-25 N BROAD ST Issued June 11, 2018 Comment

Jun 09

  • USE PERMIT

    FOR A SIT-DOWN RESTAURANT AND EXISTING FOOD BEVERAGES AND GROCERIES AT SPACE# B AS PART OF EXISTING STRUCTURE ON THE SAME LOT WITH ALL OTHER USES AS PREVIOUSLY APPROVED. NO SIGN ON THIS APPLICATION.

    322-44 N BROAD ST Issued June 6, 2018 Comment

Jun 06

Jun 03

  • PLUMBING PERMIT

    ALTERATIONS: INTERIOR PLUMBING; OFFICE SPACE; LAV 6 WC 4 UR 2/12 -THE INSTALLATION WILL COMPLY WITH THE PHILADELPHIA PLUMBING CODE 2004

    330-48 N 12TH ST Issued May 31, 2018 Comment

May 31

  • USE PERMIT

    FOR A FOOD, BEVERAGES AND GROCERIES AT SUITE # B AS PART OF EXISTING STRUCTURE . NO SIGN ON THIS APPLICATION.

    322-44 N BROAD ST Issued May 29, 2018 Comment

May 27

  • ALTERATION PERMIT

    PARTIAL CHANGE OF OCCUPANCY & LEVEL 2 ALTERATIONS TO CREATE A GROUP MEDICAL HEALTH CLINIC W. ANCILLARY DAY CARE SPACE AT 1ST FLR OF EXIST. MIXED-USE HIGH-RISE BUILDING IN ACCORDANCE WITH APPROVED INCLUDING ERECTION OF PARTITION WALLS FOR EXAM, TREATMENT, WAITING, & DAY CARE SPACES & ALL ASSOCIATED FINISH WORK; BUILDING IS FULLY SPRINKLERED. SEPARATE PERMIT REQ'D FOR ANY MECH., ELEC., PLUMB., & FIRESUPP WORK.

    330-48 N 12TH ST Issued May 25, 2018 Comment

May 25

  • PLUMBING PERMIT

    CIT FAI MAIN DRAIN 2" WATER PA 1 CALL 20181073108

    251 N 12TH ST Issued May 23, 2018 Comment
  • ELECTRICAL PERMIT

    DEMO, SAFE OFF AND PROVIDE 1200AMP TEMPERARY ELECTRICAL SERVICE, LIGHINT AND POWER FOR FUTURE CONSTRUCTION, 100 STRINGERS & 200 HI BAY LED LIGHTS AS PER 2008 NEC (CC DISTRICT)

    400 N BROAD ST Issued May 23, 2018 Comment

May 23

  • ELECTRICAL PERMIT

    REPLACE EXISTING 100AMP BREAKER PANEL SAME SIZE, REPLACE PAINTED RECEPTS, EXIT/EM & REMOTE HEAD, 5 BAD DIMMERS & 2 CEILING LIGHTS AS PER 2008 NEC (CC DISTRICT)

    1433 ARCH ST Issued May 21, 2018 Comment
  • ELECTRICAL PERMIT

    ADD (1-3) 600AMP FEEDER & PANELS, (1-3) 100AMP BREAKER, FEEDER AND PANELS, ADD 3 STEP DOWN TRANSFORMERS AND (3) 208 VOLT PANELS, 12 LINES AND CONNECTION TO MECHANICAL EQUIPMENT, 1 GAS BOOSTER PUMP LINE, 6 DUPLEX RECEPTS AS PER 2008 NEC (CC DISTRICT)

    339 N BROAD ST Issued May 21, 2018 Comment