5 days ago

  • PLUMBING PERMIT

    REPLACE CURB TRAP AND FAI PA20181832308 "SELF-CERTIFICATION'S ARE NO LONGER PERMITTED" - "ALL EXCAVATIONS AND PLUMBING TRENCHES IN EXCESS OF 5 FEET IN DEPTH MUST HAVE APPROVED SHORING IN PLACE AT THE TIME OF INSPECTION"

    5235 N SYDENHAM ST Issued July 9, 2018 Comment
  • ELECTRICAL PERMIT

    INSTALL A DISCONNECT SWITCH... PER 2008 NEC FOR A ONE FAMILY BUILDING

    1840 SULIS ST Issued July 9, 2018 Comment

Jul 07

  • ALTERATION PERMIT

    REMOVE OLD ROOF COVERINGS AND INSTALL NEW ROOF COVERINGS

    5251 N SYDENHAM ST Issued June 28, 2018 Comment

Jul 05

  • ALTERATION PERMIT

    REMOVE EXISTING BUILT UP ROOFING SYSTEM AND ASSOCIATED FLASHINGS AND EDGE METAL. INSTALL NEW INSULATION, MODIFIED ROOFING SYSTEM IN COLD ADHESIVE AND ALL ASSOCIATED FLASHINGS. INSTALL NEW FLASHINGS AND ROOF DRAINS AS WELL.

    1701 LINDLEY AVE Issued July 2, 2018 Comment
  • ALTERATION PERMIT

    MAKE SAFE PERMIT-IN ACCORDANCE WITH CODE BULLETIN PM-1801, A PA PROFESSIONAL ENGINEER IS REQUIRED TO MONITOR REPAIRS MADE UNDER THIS PERMIT. THE ENGINEER MUST SUBMIT A SEALED STATEMENT TO THE DEPARTMENT CONFIRMING THAT THE STRUCTURE IS IN SOUND CONDITION AT COMPLETION TO RESOLVE CASE #625986. ABUTTING SIDEWALK MUST BE CLOSED WITH FENCING A MINIMUM OF 6' IN HEIGHT. SEPARATE STREETS DEPARTMENT PERMIT REQUIRED FOR SIDEWALK CLOSURE. A SEPARATE PERMIT IS REQUIRED FOR ANY ADDITIONAL ALTERATIONS THAT ARE NOT SPECIFICALLY ADDRESSED ON CASE #625986.

    1626 LINDLEY AVE Issued June 29, 2018 Comment

Jun 29

  • PLUMBING PERMIT

    5" COMBINATION SYSTEM (STORM/SANITARY) HOUSE TRAP AND FRESH AIR INLET REPLACEMENT - "SELF-CERTIFICATIONS ARE NO LONGER PERMITTED" - "ALL EXCAVATIONS AND PLUMBING TRENCHES IN EXCESS OF 5 FEET IN DEPTH MUST HAVE APPROVED SHORING IN PLACE AT THE TIME OF INSPECTION

    5022 N 15TH ST Issued June 26, 2018 Comment

Jun 24

Jun 23

  • ELECTRICAL PERMIT

    INSTALL EXHAUST FAN... PER 2008 NEC FOR A ONE FAMILY BUILDING (PAID FOR BY PHDC)

    1824 W ALBANUS ST Issued June 21, 2018 Comment

Jun 03

  • ELECTRICAL PERMIT

    NEW 100A SERVICE COMPLETE W/METER AND PANEL. REPLACE DEFECTIVE RECEPTACLES, SWITCHES, FIXTURES. INSTALL SMOKE ALARM, 6- 15/20/30A LINES, 2- SWITCH & LIGHT COMPL... PER 2008 NEC FOR A ONE FAMILY BUILDING

    4922 N SMEDLEY ST Issued May 31, 2018 Comment

May 20

  • ALTERATION PERMIT

    SHORING AND PARTIAL DEMOLITION, THEN REBUILDING OF MASONRY WALLS AT FRONT AND SIDE OF VESTIBULE ON AN EXISTING SINGLE-FAMILY DWELLING AS PER ENGINEER'S SEALED PLANS

    1715 WAGNER AVE Issued May 17, 2018 Comment